Appendix A — Planned Developments
PD - 1 - Eaton Canyon Industrial Park
PD - 3 - Kinneloa Annexation
PD - 4 - Mountain Street Classics Townhomes
PD - 5 - Allesandro Place/Fair Oaks
PD - 6 - Eaton Wash Residential
PD - 7 - Seco Street
PD - 9 - El Mirador
PD - 10 - Colorado/Lake
PD - 11 - Foothill Boulevard, Craig Avenue and White Street
PD - 12 - Walnut-Los Robles
PD - 13 - Marengo-Bellevue
PD - 15 - Huntington Hotel
PD - 16 - Jet Propulsion Laboratory (Employee
Parking)
PD - 17 - Rose Townhomes
PD - 18 - Colorado/El Nido
PD - 21 - Montgomery Engineering
PD - 22 - Lincoln Triangle Townhouses
PD - 23 - Salvation Army
PD - 24 - South Lake Avenue Development
PD - 25 - Vista Del Arroyo Bungalows
PD - 26 - Colorado - Los Robles
PD - 27 - King's Village
PD - 28 - Community Arms
PD - 29 - Artisan Square
PD - 31 - Montana I and II
PD - 32 - Rose Avenue
PD - 1 - Eaton Canyon Industrial Park
-
Permitted
Uses. The following are
permitted
uses in PD-1:
offices:
business and professional;
laboratories;
industry, standard; and
industry,
restricted.
- Conditional
Use Permit Requirement. A Conditional
Use Permit shall
be required for the construction of a new
building or construction of an
addition to an existing
building.
-
Development Standards.
-
Projects
should be in accordance with the plan entitled, "Specific Plan 26.46 Acres of
Land, 3100 New York Drive, Pasadena, California," dated November 1977 on file
in the office of the
city clerk.
- The
minimum parcel size on the
site shall not be less than 2.5 acres.
- Vehicle
access shall be provided only from Bradley
Street or from such access points as
existed prior to the adoption of the aforementioned
specific plan.
-
Building
coverage on each parcel shall not exceed 35 percent of the total area of each
parcel.
-
Buildings
shall be set back a minimum of 40 feet from all
street frontages and shall be
compatible in appearance with
setbacks of adjacent
buildings.
- No
off-site parking shall be
permitted.
- Signing
shall be compatible on all parcels and shall be of high quality. Wall signs and
monument ground signs will be
permitted.
- All
parcels will be landscaped a minimum of 20 percent of the total area of each
parcel.
- The
following shall be visually screened from public view:
- Shipping
and receiving doors;
- Roof
mounted equipment, with the exception of noise suppression equipment for 2900 Bradley
Street;
- Storage
and trash areas.
- No
use shall be
permitted which will involve odors or other emissions incompatible
with the character of the area and which may be detrimental to surrounding
properties.
- No
building shall exceed two stories or 36 feet in
height, with the exception of
unscreened noise suppression equipment for 2900 Bradley
Street.
- All
structures on the
site shall be designed to be architecturally compatible in
terms of materials and expense.
PD - 3 - Kinneloa Annexation
- Conditionally
Permitted
Uses.
- All
uses
permitted in the CG
District shall be conditionally
permitted except that
no commercial
development shall be allowed where it would cause an adjacent
residential use to have
commercial uses on 2 side lines. Hours of operation of
commercial uses shall be limited to between 7:00 a.m. and 9:00 p.m.
All developments shall abide by residential noise standards
as established in
Section 9.36 of the Pasadena
Municipal Code.
-
Street
Access. Except for
developments which conform with the requirements of the RS
District (
Chapter 17.20), there shall be no vehicular access to Green
Street.
- Parking
Requirements. All uncovered parking areas shall be screened according to the
provisions of
Section 17.68.150. No parking shall be allowed in any required
yard.
-
Building
Height Limit. No
building in the PD-3
District shall exceed 11/2 stories or 22 feet in
height.
- Stepbacks.
For every
building in the PD-3
District over 20 feet in
height above the
adjacent finished
grade of a contiguous property in an R
District, 3 feet of
stepback shall be required for each additional 10 feet of vertical
height or
fraction thereof. No stepback shall be required adjacent to an
alley.
- Side
and Rear Yards. There shall be no side or
rear yard required in the PD-3
District, unless the side or rear line is adjacent to a property with a
residential use, in which case a
yard of not less than 5 feet shall be
provided.
-
Yards
Adjacent to
Street. There shall be a front or
side yard
abutting every
lot line
adjacent to a
street. Such
yards shall be governed by the requirements of
Chapter 17.20 (RS
District). Every
yard in the PD-3
District
abutting a
street
shall include a landscaped area not less than 5 feet wide along the length of
the yard. There shall be no
yard required along an
alley.
-
Landscaping.
A landscape plan shall be submitted to and approved by the
Zoning Administrator
prior to issuance of any Conditional
Use Permit. All landscaped areas shall be
provided with a permanent underground irrigation system. One hundred percent of
all landscaped areas shall be planting areas. The landscape plan shall include
plant materials placed so as to grow to screen walls, fences and interior
uses.
- Findings Required. In addition to the findings required by
Chapter 17.88
of this title, the following findings shall be made in the affirmative in the
action of the
hearing officer in granting a Conditional
Use Permit in the PD-3
District.
- That
the development will not be detrimental to the residential character of the
area.
- That
the development will not "landlock" any residential parcel,
as specified in
Section A1 of the PD-3
District
development standards.
PD - 4 - Mountain
Street Classics Townhomes
- Land
Use. The following land
uses shall
be permitted:
- Residential:
Single-Family; Multifamily;
Adult Day Care, Limited; Small
Family Day Care
Home; and
Residential Care, Limited;
- Commercial:
Commercial
Filming with a
filming Conditional
Use Permit;
-
Accessory:
Home Occupation; and other
accessory uses reasonably related to the
permitted
uses as determined by the
Zoning Administrator;
-
Temporary:
Commercial
Filming, Limited;
Personal Property Sales;
Street Fairs; and
Tents,
except that a
temporary Conditional
Use Permit shall be required if any of the
following conditions occur:
- The area
covered by tents exceeds 800 square feet;
-
Tents are
located on the
site more than 36 hours;
-
Tents are on the
site more than twice in a calendar year.
-
Density. The maximum number of units shall be 46 residential units.
-
Development
Standards. New construction shall
substantially conform to Exhibit C, entitled "Illustrative
Site Plan: Mountain
Street Classics," dated May 22, 1996 (hereinafter, Exhibit C), and herein
incorporated by reference. In addition, the following
development standards
shall apply:
- Maximum
Lot Coverage. The maximum
lot coverage shall be 35 percent for the
site classified as
PD-4, to include the portion of the
site covered by roofs, soffits, or
overhangs extending more than 3 feet from a wall and by decks more than 4 feet
in height measured from finish
grade. Roofs with openings or perforations 50
percent or greater of the surface area of the roof shall not be included in the
lot coverage calculations. For the purposes of calculating
lot coverage, the
lot area includes the area of private
streets and driveways.
- Minimum
Yards. The minimum
yards shall be as follows:
- A
yard with a
minimum of 20 feet in depth shall be provided along the Mountain
Street and
Lincoln Avenue
property lines and shall be planted in its entirety between the
property line and the
occupancy frontage, except for walkways, driveways, and
private patios;
- A
yard with a
minimum of 5 feet in depth shall be provided along all other
property lines;
- A
yard with a minimum of 5 feet in depth shall be provided along private
streets.
-
Yard Encroachments. The
permitted encroachments into minimum
yards shall be as
follows:
- A maximum
projection of up to 5 feet into the
yards along the Mountain
Street and Lincoln Avenue
property lines may be
permitted for the following encroachments:
- Balconies;
- Open porches
no higher than one
story;
- Bays no
greater than 10 feet long and no higher than two stories (with a frequency no
greater than one bay per 15 feet of
building wall);
- Uncovered
steps, landings, or patios not more than 3 feet in
height measured from finish
grade;
- Uninhabitable
encroachments such as chimneys and projecting eaves.
- A maximum
projection of up to 3 feet into all other
yards may be
permitted for the
following encroachments:
- Uncovered
steps, landings, or patios not more than 1 foot in
height measured from finish
grade and no more than 10 feet in length measured parallel to the
building;
- Uninhabitable
encroachments such as chimneys and projecting eaves.
-
Building
Separation. The minimum separation between
buildings shall be as follows:
- Separation
Between Buildings on Adjacent
Lots. A
yard of 8 feet between any
property line
and any portion of
building wall which contains doors or windows shall be
provided as follows:
- When any
portion of new building wall is within 15 feet or less of a facing wall of any
existing (principal or
accessory) structure on an adjacent
site where either
wall contains a window or aggregate of windows 16 square feet in size or more,
or a door;
- When any
portion of new building wall is within 10 feet or less of a facing wall of any
existing (principal or
accessory) structure on an adjacent
site where either
wall contains a window or aggregate of windows less than 16 square feet in
size;
- In cases where
the requirements for separation between
buildings on adjacent
lots and the
minimum yard requirements of paragraph 2 herein conflict, the more stringent
requirements govern.
- Separation
between Buildings on the Same
Lot. A minimum separation between
buildings
shall be provided as follows:
- A minimum
separation of 15 feet between
buildings on the same
lot shall be provided for
any portion of new
building wall facing another
building wall where either wall
contains a window or aggregate of windows 16 square feet in size or more, or a
door;
- In all other
cases, a minimum separation of 10 feet between
buildings on the same
lot shall
be provided;
- In cases where
the requirements for separation between
buildings on the same
lot and the
landscaped courtyard requirements of paragraph 6 herein conflict, the more
stringent requirements govern.
- Encroachments
into Minimum Separations Between
Buildings. Uninhabitable encroachments such
as chimneys and projecting eaves may
project a maximum of 3 feet into any
minimum separation between
buildings on either adjacent
lots or the same
lot.
-
Building
Orientation.
Buildings shall have
individual unit entrances articulated by such architectural elements as stoops,
overhangs, ornamental hoods, or porches. In addition,
buildings shall be
oriented as follows:
-
Buildings facing
Mountain Street and Lincoln Avenue shall have:
- Individual
unit entrances facing or
visible from the
street;
-
Street facades
with windows or an aggregate of windows 16 square feet in size or more, or
doors.
- All other
buildings. The majority of
buildings not facing public
streets shall face
common open spaces such as landscaped courtyards or recreation areas, as
provided for in Exhibit C, and meeting the requirements of paragraph 6 herein.
In addition, all
buildings shall have:
- Individual
unit entrances facing or
visible from a private
street or common
open spaces;
-
Building
facades with windows or an aggregate of windows 16 square feet in size or more,
or doors, for any facade facing a private
street or common
open spaces.
- Common
Open Space Areas. Common
open spaces
to include but not limited to landscaped courtyards and recreation areas
provided as part of the paragraph 5 herein shall be
visible from a public or
private street and shall have a minimum dimension of 25 feet. At least 50% of
landscaped courtyards shall be planted. Encroachments
permitted to
project for
a maximum projection of up to 5 feet into such common
open spaces shall be as
follows:
- Balconies;
- Open porches no
higher than one
story;
- Bays no greater
than 10 feet long and no higher than two stories (with a frequency no greater
than one bay per 15 feet of
building wall);
- Uncovered steps,
landings, or patios not more than 3 feet in
height measured from finish
grade;
- Uninhabitable
encroachments such as chimneys and projecting eaves.
- Maximum
Height. The maximum
building
height
shall be 23 feet to the
top plate and 36 feet to the highest ridgeline, with
height measured from finish
grade. Chimneys may exceed the
permitted
height by
no more than 2 feet.
-
Open
Space. A minimum of 35 percent of
the site classified as PD-4 shall be
open space, to include but not limited to
landscaped areas, recreation areas, private patios, courtyards, and walkways no
more than 4 feet in width. All
open space areas shall be finished with
landscaping or decorative paving.
- Paving
Standards. The following paving
standards shall apply:
- Concrete may be
used for walkways up to 4 feet in width but is not acceptable for area paving
unless mandated by the Uniform
Building
Code;
- Unplanted areas
with a minimum dimension of 5 feet or more shall be paved with unit pavers such
as brick, tile or concrete setts or covered with decomposed granite or
garden
gravel.
-
Landscaping
and Maintenance. Landscaped areas
shall be permanently maintained and irrigated with an automatic system in
accordance with the provisions of
Chapter 17.64. The majority of landscaped
areas shall be planted with low water-using plants. Grass shall be excluded
from areas difficult to irrigate, such as sidewalk strips, slopes, and planting
areas less than 5 feet in width. At least one 24-inch-box tree shall be
planted for each residential unit and for each tree removed from the
project
site. New trees shall be distributed throughout the
site. A landscape plan
shall be submitted for review and
approval by the Planning
Director prior to
issuance of a
building permit and shall contain the specimen or common names of
plants, sizes, location on the
site, and number of each variety
used.
- Walls and
Fences. Walls or fences located
between a public or private
street and any
occupancy frontage may be to 6 feet
in height provided that the material
used for the fence or wall for any portion
of the wall above 4 feet has perforations through at least 50 percent of its
surface area. Walls or fences along
property lines adjacent to any PS
district
may be up to 10 feet in
height. A wall or fence in a landscaped courtyard as
described in paragraph 6 herein for common
open space areas, or a wall or fence
between a public or private
street and such landscaped courtyard, shall not
exceed 4 feet in
height. Walls and fences bordering a private patio or private
open space within said landscaped courtyard may be up to 6 feet in
height,
provided that the material
used for the fence or wall for any portion of the
wall above 4 feet in
height has perforations through at least 50 percent of its
surface area. All other interior walls or fences may be up to 6 feet in
height
without limitation on the material
used. Walls or fences near intersecting
streets or driveways must comply with the sight distance triangle provisions of
Section 12.12.020.
- Off-Street
Parking. The applicable standards of
the off-street loading and parking
regulations of
Chapter 17.68 shall apply,
except as here modified. A minimum of 2 covered
parking spaces shall be
provided on site for each unit. All covered
parking spaces shall be equipped
with automatic
garage door openers. A minimum of 9 uncovered
parking spaces
for guest parking shall also be provided
on site.
-
Accessory
Structures.
Accessory
structures
shall be permitted as follows:
-
Accessory
structures shall not be constructed prior to the construction of a
primary
structure;
-
Accessory
structures may be located in a minimum
yard, except that such
structures shall
not be permitted between a public
street
property line and any
occupancy
frontage, and in any
yard within 100 feet of a
street
property line.
Accessory
structures shall maintain a minimum separation of 6 feet from any other
structure on the
lot.
-
Accessory
structures shall be limited to one
story with a maximum
height of 18 feet and a
maximum top plate
height of 12.5 feet. An
accessory structure shall be limited
to a maximum height of 12 feet in
height at the
property line and shall not
intercept an inclined daylight plane slope inward from a point 12 feet above
the property line and rising 2 feet for each foot of distance from the
property
line. Eaves may
project into the inclined daylight plane slope;
-
Accessory
structures shall be limited to
uses which are
accessory to the main
use,
including but not limited to,
garage or
carport, pergola, pool, or
hot tub and
related equipment, greenhouse, cabana, gazebo or workshop;
- Pools, spas, and
related equipment shall not be closer than 5 feet from a
property line;
- No
swimming
pool or hot tub shall be located closer than 15 feet, measured in a horizontal
plane, to any unenclosed balcony, porch, landing or access way which is more
than 8 feet above the elevation of the
adjoining pool deck or coping, if there
is no deck. Windows above the first floor within 15 feet of a
swimming pool
shall be fixed.
- Signs. The following sign standards shall apply:
- On-Premise
Signs. No sign shall be located more
than eight feet above the finish
grade. Signs near intersecting
streets or
driveways must comply with the sight distance triangle provisions of
Section 12.12.020.
Illumination of signs shall be
permitted as established in
Section 17.72.050. The following additional
regulations shall apply:
- Mountain
Street and Lincoln Avenue. A maximum
of two wall or freestanding signs for
project identification along the combined
Mountain Street and Lincoln Avenue
property lines may be
permitted. The
maximum sign area shall be 16 square feet of total sign area for the combined Mountain
Street and Lincoln Avenue
street frontages.
- Manzanita
Avenue. One wall or freestanding sign
may be permitted along the Manzanita
Street
property line, not to exceed 3
square feet of sign area.
- Exempt and
Prohibited Signs. The provisions of
Section 17.72.020 and
Section 17.72.060 governing exempt signs and prohibited
signs, respectively, shall apply.
-
Temporary
Real Estate Signs. The following
standards for
temporary real estate signs shall apply:
- During
construction and prior to the issuance of a certificate of
occupancy, there
shall be no limitation on the number or size of
temporary real estate signs
advertising the property for rent, lease, or sale.
- Following the
issuance of a certificate of
occupancy, no more than 2 signs advertising the
property for rent, lease, or sale shall be
permitted for any
street frontage.
No sign shall exceed 3 square feet in area.
- Screening
of Mechanical Equipment. The
provisions of
Chapter 17.64 governing the screening of mechanical equipment
shall apply, except as modified herein. All exterior mechanical equipment
shall be screened from view from public or private
streets, driveways,
recreation areas, common areas, and walkways. Exterior mechanical equipment
may be located in any minimum
yard, except no such equipment shall be located
between a public
street and any
building line. The top of exterior mechanical
equipment need not be screened from view from above.
- Refuse
Storage Areas. The provisions of
Chapter 17.64 governing refuse storage shall apply. The Public Works
director
shall determine the minimum size of required refuse storage area based on the
type of use, the size of the refuse area proposed, and the frequency of refuse
collection.
- Performance Standards. The performance standards in
Chapter 17.64 shall apply.
- Design
Review. The
project shall be subject
to Design Review and
approval as required by
Chapter 17.92. In addition, the
Planning
Director shall review and approve all new construction or substantial
exterior
alterations affecting views of the
project from the
public
right-of-way or a significant portion of the
site. All other exterior
alterations shall be exempt from Design Review.
- Public
Rights-of-Way. All unused drive
approaches shall be closed with standard concrete curb, gutter, and sidewalk.
The driveway access from Mountain
Street shall be a minimum of one hundred feet
from the 210 Freeway
public right-of-way. In addition, the following
improvements as specified by the Public Works
Director shall be required prior
to the issuance of a certificate of
occupancy:
- Mountain
Street shall be restriped to allow
left-turns to/from the driveway access on Mountain
Street;
- A minimum of 3 new
street lights shall be provided;
- A maximum of up to 6 new 24-inch-box
street trees shall
be installed along the
project
street frontage.
-
Lot Consolidation. A tentative tract map to
consolidate the existing
lots and for condominium purposes shall be filed
within 6 months of the issuance of a
building permit and prior to receiving a
certificate of
occupancy. The tentative tract map shall include any dedicated
easements, as required, for sewer, storm drain, public utilities, or
ingress/egress purposes in accordance with the requirements and standards of
the Public Works
Director. If the tentative tract map is approved, the
applicant or successor in interest shall record a final tract map within the
time period allowed under the
Subdivision Map Act of California
Government Code
Sections 66410 to 66499.58.
- Applicability. Any conditions and
mitigation measures adopted as
part of any required
approval for the
project, as well as the
code requirements
of other
City
departments, shall remain applicable.
PD - 5 - Allesandro Place/Fair Oaks
- Conditionally
permitted
uses shall be those restricted to and directly supportive of hospital
uses. Such
uses include
medical
offices,
laboratories, clinics and other such
facilities that are medically oriented as well as ancillary automobile parking.
The
property facing Hurlbut
Street shall specifically be restricted to
surface
parking.
- No
new structure shall exceed 50 feet in
height excluding mechanical equipment.
Parking
structures shall be limited to 2 stories above
grade. Maximum
lot
coverage shall be limited to 45 percent.
-
Front
yard
setbacks shall be required and shall not be less than 20 feet. Side and
rear yard
setback shall not be less than 10 feet.
- Parking
shall be provided in accordance with the requirements of
Chapter 17.68 of this
title.
- Vehicular
access from Hurlbut
Street shall be limited to ingress only. Vehicular egress
shall be prohibited onto Hurlbut
Street. Parking on the parcel facing Hurlbut
Street shall be restricted to employee parking only.
PD - 6 - Eaton Wash Residential
The following zoning standards
shall apply and supersede any inconsistent or different standards established
by Title 17 of the Pasadena
Municipal Code, but only for the
development plan
referred to in
Section 4 of Ordinance 5595. Except as expressly provided
herein, a planned unit
development for the area shall comply with all the
requirements of the Pasadena
Zoning Code that may be applicable to the area.
The special
development standards are as follows:
-
Density and
Lot Area. The
project
density shall not exceed 55 units nor 4.9
dwelling units per gross acre (development
site plus half the width of Sierra
Madre and Orange Grove Boulevards). No
lot shall be less than 4500 square feet.
-
Building Area.
Building area shall not exceed 50 percent of the total
lot area.
-
Yards and
Setbacks.
- The
depth of the
front yard shall be a minimum of 22 feet from the front
property
line.
- There
shall be a minimum 10 foot
side yard along one
side lot line of every
lot. A
second side yard along the other
side lot line is optional.
- Each
lot shall have an average 23-foot
rear yard
setback.
-
Landscaping. One 36-inch box tree shall be
planted on each
interior lot. Two 36-inch box trees shall be planted on
corner
lots. An automatic irrigation system shall be installed in the
front yards,
along
side yards adjacent to
streets and along any common area. Existing
Jacaranda trees shall be retained.
- Parking.
- All
driveways shall be paved with concrete.
- Automatic
garage door openers shall be provided for each unit.
- Elevations. There shall be a minimum of two
elevations for each floor plan.
PD - 7 - Seco
Street
- Conditionally
Permitted
Uses.
- Business
services including, but not limited to, printing, duplicating, blue printing,
secretarial services, computer services, mailing services, telephone exchange
and photographic processing.
- Business
and professional offices and
medical
offices.
- Other
business related
uses which are found to be consistent with the intent of the overlay zone.
Specifically
prohibited are
retail sales of any kind, eating establishments, automotive
related uses and personal service
uses (cleaning, barber shop, laundry, shoe
repair, etc.).
- Required
Setbacks. The minimum
building
setback shall be 15 feet from all
streets.
-
Height Limit. No
structure shall exceed the elevation of 30 feet from
the datum plane on Seco
Street.
-
Building Coverage. The maximum coverage of all
structures on a
lot shall
not exceed a maximum of 50 percent.
- Sign Limitations. Signs shall be
permitted only in accordance with the
sign regulations for the RM-32
District.
-
Building Design. All
structures shall be residential in character, and
shall have exterior surface
building materials limited to wood and stucco (no
masonry or glass
buildings); rooftop mechanical equipment shall be totally
screened in accordance with the provisions of
Chapter 17.64 of the
zoning code.
- Required
Landscaping. A minimum of 15 percent of the
site area shall be
planting area.
- Access. Vehicular access shall be
permitted to Seco
Street only.
PD - 9 - El Mirador
- The
average lot area (exclusive of the
open space
lot) shall be not less than
22,586 square feet, and no individual
lot area may be less than 15,000 square
feet.
-
Lot width shall be not less than 100 feet at the front
building line.
- Special
construction and
site requirements of the HATE
District and the required width
and grade requirements for driveways of such
district shall be strictly
followed.
-
Developments
on the
lots designated 5, 6 and 12 on revised Tentative Tract Map 41465 shall
be subject to
building criteria developed by the
Zoning Administrator. The
City
Council shall adopt the
building criteria reasonably necessary to implement
this development standard at the first quarterly review of this planned unit
development.
- The
"Wabash Knoll" shall not be physically altered.
- All
cut and fill slopes shall be contoured to meet side slopes with radii of at
least 25 feet and to meet upper and lower slopes with radii of at least 10
feet.
- The
development shall comply with the parking requirements of the HATE
District.
- The
street width shall be 32 feet curb to curb. A 5-foot wide sidewalk within a
10-foot sidewalk and utility
easement may be required on one side of the
street, and an 18-inch to 3-foot wide carriage walk may be required on the
other side of the
street.
-
Street
grade shall not exceed 12 percent except that 15 percent segments shall be
permitted for limited distances if the
Zoning Administrator determines that the
difficult terrain of the
site warrants such action.
- The
Zoning Administrator shall consult with
abutting property owners to determine a
mutually acceptable wall design for the periphery of the
site adjacent to the
existing residences located to the north and east.
- The
Zoning Administrator shall review and approve the final landscape plan (per
Section 17.48.040(J)) for the slope, common
open space and graded areas prior
to issuance of any permits. The landscape plan shall include the following:
- Specific
attention shall be given to retaining and enhancing the existing riparian
habitat in the upper canyon area. Plant materials
used should be appropriate to
lower foothill riparian ecosystems.
- The
developer shall consult with a biologist to ensure the debris basins provide
maximum benefit to riparian habitat. No fences or other barriers to animal
movement shall be placed along these drainages.
- Maximum
effort shall be given to retaining existing trees in place. All trees to be
retained in places shall be suitably protected during grading operations. For
trees to be removed, emphasis shall be placed on transplanting them
on site.
For each native tree larger than 4-inch caliper which is removed and not
transplanted
on site, a replacement tree shall be planted on the
site. For
trees in excess of 8-inch caliper, the replacement tree shall be 48-inch box or
larger, or a combination of sizes to be approved by the
Zoning Administrator.
All trees shall be planted prior to release of the letter of credit described
in paragraph N below and shall be maintained by the
applicant or his
successor(s) in interest until the individual
lots are transferred to
individual ownership or to a homeowners association.
- On
completion of final grading, the
developer shall replant and irrigate
cut-and-fill slopes so that revegetation can occur as soon as possible.
Consideration shall be given to
use of drought adapted, fire-retardant plant
materials, especially species native to Southern California foothills.
- The
developer shall provide a complete irrigation plan. If water requiring species
are used for rapid growth, a water injection system shall be installed rather
than sprinkling systems. No irrigation system shall be
permitted in areas of
existing natural vegetation.
- To
minimize entry of sediment into preserved drainage courses, resulting from
construction, consideration should be given to
use of rapid developing soil
anchoring ground cover and strategic placement of run-off retaining
structures.
-
Landscaping
shall screen views of downslope elevations to the extent
feasible.
- Areas
where fuel loads constitute a significant fire threat shall be cleared or
thinned of existing plant material to the satisfaction of the fire
department.
- Topsoil
shall be stockpiled during grading and redistributed on appropriate surface areas
during the fine grading operation.
- Prior
to release of the letter of credit, the
Zoning Administrator shall find that
the applicant has complied with the landscape plan, and that the ground cover,
shrubs and trees on the graded slopes are planted and established.
- The
Zoning Administrator shall review and approve a complete grading plan prior to
issuance of any permits. The grading plan shall include the following:
- Hauling
route and schedule which provides the least impact to surrounding residents.
- Maximum
use of passive drainage controls (landscaping, small diversion basins, etc.) as
opposed to active control devices (paved swales, below
grade storm drain
systems, etc.).
- Phased
grading and tree removal plan in order to retain escape routes for native
fauna.
- Strict
conformance to the standards of
Municipal Code Chapter 14.05 (Excavation and
Grading of Hillsides), including slope gradients.
- Minimum 95 percent compacting in the upper 12 inches of all
street
subgrades.
- Excavation and refilling (with compacted fill) in areas of porous,
compressible or alluvial soils where
buildings are to be located.
- Stockpiling for later reuse of topsoil.
- During grading operations, the soil shall be watered down to prevent escape
of airborne dust.
- Cut and fill activity shall substantially balance so that earth import or
export does not exceed 15,000 cubic
yards.
- The
height of cut slopes shall not exceed 20 feet.
- The maximum
height of finished cuts for roads, walkways, walks and driveways
shall not exceed 8 feet unless such cut is also necessary for the formation of
a pad in which case 20 feet is the maximum
height.
- The
height of fill slopes shall not exceed 30 feet.
- Debris basins shall be constructed to the Los Angeles County Flood Control
District standards.
- The
developer shall submit a covenant approved by the
city attorney's
office to ensure that the following standards are met:
- All homes shall have noncombustible roofs.
-
Street-facing windows of units shall be constructed with double-paned
windows and/or other attenuation measures as needed to reduce interior noise
below 45 decibels.
- The
developer shall make the following recommendations to the purchasers of
the lots with respect to crime prevention methods:
- Exterior doors should be metal or solid wood with a 1-inch deadbolt that
locks in addition to a key-in-the-knob lock.
- When a door has glass panes or windows within 40 inches of a lock, a double
cylinder deadlock is recommended so that a key is required to open the door
from either side.
- All ground floor windows should have key operated sashlocks.
- To prevent sliding glass doors from being lifted from the track, it is
recommended that 1-1/4 inch pan head sheet metal screws be inserted into the
top of the door frame at both ends and the middle so that the door barely
clears them when it is operated.
- Sliding glass doors should be fitted with deadlocks which utilize bore pin
tumbler cylinders.
- No truck traffic to or from the
site during initial
site grading shall
occur during the time period when school busses pick up and drop off children
on El Mirador Drive.
- All grading,
landscaping and irrigation systems and public improvements
shall be complete within 18 months of initial grading activity.
- Local
streets
used by trucks and equipment servicing this
project during
construction shall be washed down daily if necessary. Any damage to public
streets as a result of the grading activity shall be repaired at the expense of
the developer.
- Bylaws for the formation of a homeowners' association.
- Homeowners' association conditions, covenants and restrictions (CC&R's)
indicating:
- The permanent dedication of the
open space
lot for
open space
uses. Ownership
of the open space
lot shall be transferred to the homeowners' association in
perpetuity for maintenance and assumption of all liability.
- Continued maintenance program for debris basins, slopes and vacant
lots which
provides for maintenance by the
applicant or his successor(s) in interest until
the individual
lots are transferred to individual ownership or to a homeowners'
association.
- Continued maintenance program for debris basins, slopes and vacant
lots which
provides for maintenance by individual
lot owners, or by a homeowners'
association until construction begins on the
lots.
- Method of financing for such continued maintenance program.
- Construction shall be limited to weekdays between 7:00 a.m. and 5:00 p.m.
- The
developer shall notify prospective
lot purchasers of Southern California
Gas Company's program to provide assistance in selecting the most effective
energy conservation techniques for a
development.
- Design and construction methods shall include passive solar water heating and
space heating/cooling where practical and incorporation of natural ventilation
techniques such as:
- South-facing overhangs;
- Shading of windows where practical;
- Heat absorbing window screens;
- Double glazed or other high-STC rated windows for noise abatement and energy
savings;
- Insulate hot water heater and pipes;
- Locate water heater as close as possible to areas needing hot water;
- Clock or electronic thermostat controlled space conditioning system to automatically
switch off equipment during nonoccupancy hours;
- Place heating/cooling equipment near points of
use; and
- Locate thermostats where they will accurately measure temperatures
experienced by people.
- The
developer shall provide a letter of credit approved by the
city
attorney's office and the planning
director to ensure that the grading
project
(including the construction of drainage and protective devices and any
corrective work necessary to remove and eliminate engineering and geological
hazards),
landscaping, irrigation systems and public improvement requirements
contained in the
development standards and subsequent conditions of
subdivision
approval will be completed within 18 months of initial grading activity.
- The
applicant shall provide a letter of credit approved by the
city
attorney's office and the planning
director to ensure that there is continued
maintenance of debris basins, slopes and vacant
lots after the expiration of
the 18-month period discussed in paragraph N above. Such maintenance shall
continue until the
developer has sold 50 percent of the
lots at which time the
homeowners' association shall assume responsibility for such maintenance.
PD - 10 - Colorado/Lake
-
Permitted
uses shall be limited to office and retail
uses and the parking
required therefore.
- The overall
height of the office
building shall not exceed 161 feet.
-
Setbacks for the major mass of the 10-story office
building shall be 14.5
feet from Colorado Boulevard and 18.5 feet from Lake Avenue, except at the
northeast corner of Colorado Boulevard and Lake Avenue where the major mass of
the building will be
set back 54.5 feet from Colorado Boulevard and 58.5 feet
from Lake Avenue.
-
Applicant may construct a glassed-in entrance lobby within the northeast
corner
setback described in subsection C above, provided that such lobby does
not exceed 40 feet in width by 40 feet in length or 20 feet in
height.
- The colonnade shall be
set back 4.1 feet from Lake Avenue and shall not
exceed 20 feet in
height. It shall not extend more than 14.5 feet from the
major mass of the
building except at the northeast corner, where it shall not
extend more than 14.5 feet form the glassed-in entrance lobby described in
subsection D above.
- The office
building shall not exceed 200,827 gross square feet,
excluding the mechanical penthouse.
- The office
building shall not exceed 22,367 square feet in
lot coverage.
- The
height of the parking
structure shall not exceed 55 feet above the
finished
grade to the top of the roof wall.
- The parking
structure shall be
set back 6 feet from Boston
Court and
67.2 feet from Mentor Avenue.
- The parking
structure shall not exceed 24,422 square feet in
lot
coverage and shall contain not less than 674
parking spaces of which 241 may be
small car
parking spaces.
- The parking
structure surface shall be treated to reduce tire noise and
be designed to accommodate vans. Exhaust fans for underground parking shall be
vented to the roof of the parking
structure. The parking
structure shall be
designed to be compatible with the design of the office
building. The exterior
design of the parking
structure shall be reviewed by the
city
Zoning
Administrator and the design review committee. Architectural elements of the
parking
structure must be similar to and compatible with the proposed office
building, including the
use of exterior
building materials and color.
- Construction